PG150 | Bobcat Portable Power

Stock:
In stock

Rebates & Special Offers

View Full Offer

Get as low as 0% for 24 months* in lieu of financing.

Download Spec Sheet

Get detailed specifications, dimensions, and performance data for this PG150 | Bobcat Portable Power.

General Info
Condition: Showroom
Manufacturer: Bobcat
Model: PG150
Machine Type: Other
Engine
Engine: QSB5-G12
Engine Make: Cummins
Emissions: Tier 4 Final
Performance
Operating Weight: 6990 lb
Hydraulics
Dimensions
Height: 94.9 in
Length: 169.9 in
Width: 71.3 in
Fuel Tank: 171.6 gal

Description

PG150 Portable Generator

Cool and quiet, the Bobcat® PG150 portable generator delivers ruggedly reliable power even in the most challenging working conditions.

  • 154 kVA (123 kW) output at 69 dB(A) 
  • Powered by a Cummins QSB5-G12 engine 
  • Optional Tundra Package engineered for extreme cold  
  • Designed for easy serviceability on the jobsite

One of the coolest and quietest generators on the market, the PG150 portable generator from Bobcat features is also one of the most reliable generators able to withstand the harshest working conditions. At 100% load, it delivers 154 kVA (123 kW) of power output at a stunningly quiet 69 dB(A).

The PG150 was engineered for easy serviceability, whether on the jobsite or back at the shop. It features a user-friendly, galvanized steel enclosure design with separate compartments for the powertrain and cooling system, which utilizes radial cooling fan technology – an industry first.

Easy to tow and maneuver around the jobsite, the PG150 is powered by a Cummins QSB5-G12 engine with improved fuel efficiency, allowing the generator to run for 27 hours at 75% load. It also comes equipped with a standard dual-frequency switch that allows the generator to change from 50Hz to 60Hz.

Connection panels on the PG150 portable generator are easily accessible for improved safety and convenience. The panels also feature more power wiring connections, a terminal board that accepts bare wire or lugged cable, an array of twist-lock and GFCI receptacles, and an optional camlock panel to further expand connection versatility.

Engineered tough for a long, hardworking lifespan, the PG150 offers best-in-class serviceability for maximum productivity and uptime with 500-hour service intervals. It’s equipped with an upsized alternator with AREP, protecting against overload and short-circuiting, offering voltage stability and greater motor starting capacity. And the optional Tundra Package – added coolant heater, oil pan heater, battery charger, battery heater pad and heated breather hose – keeps the power flowing even in extreme cold (as low as -40˚F).

Answering the call for easier to read diagnostics, the PG150 features an analog control panel enhanced with large, brightly lit meters for at-a-glance monitoring. The onboard engine diagnostic display panel also contains the necessary controls and indicators that operate and maintain the aftertreatment regeneration process. 

A run/idle switch on the control panel helps to reduce unnecessary engine wear during startup, especially in extreme cold temperatures, while the voltage selector switch provides quick, easy voltage configuration. This signature safety feature protects against costly downtime by preventing operators from switching voltage during operation.

0%
for up to 24 months*
Financing Available

See participating dealers for details.

*Program disclosure: 0% A.P.R. financing for up to 24 months and offers are mutually exclusive — select one or the other. Financing subject to credit approval through an authorized Bobcat financing provider. Offer applied at time of purchase. Offers valid on qualifying new Bobcat generator models through participating dealers only. See dealer for complete details, eligibility requirements, and program end dates. Offers subject to change without notice.

PG150 Key Features

What Makes the PG150 Different

154 kVA at a Stunningly Quiet 69 dB(A)

One of the coolest and quietest generators on the market — at 100% load the PG150 delivers 154 kVA (123 kW) of power output at just 69 dB(A), and it's built to withstand the harshest working conditions.

Cummins QSB5-G12 — 27 Hr Runtime

A Cummins QSB5-G12 engine with improved fuel efficiency lets the generator run for 26.8 hours at 75% load, with a standard dual-frequency switch to change from 50 Hz to 60 Hz.

Upsized Alternator with AREP

An upsized alternator with AREP protects against overload and short-circuiting, offering voltage stability and greater motor-starting capacity.

Radial Cooling Fan — An Industry First

A user-friendly galvanized steel enclosure with separate compartments for the powertrain and cooling system, using radial cooling fan technology — an industry first — for cool, quiet operation.

500-Hour Service Intervals

Engineered tough for a long, hardworking lifespan, the PG150 offers best-in-class serviceability for maximum productivity and uptime — with 500-hour service intervals, on the jobsite or back at the shop.

Versatile, Accessible Connections

Easily accessible connection panels add more power wiring connections, a terminal board that accepts bare wire or lugged cable, an array of twist-lock and GFCI receptacles, and an optional camlock panel for even more versatility.

Easy-Read Analog Panel + Run/Idle Switch

An analog control panel with large, brightly lit meters gives at-a-glance monitoring, an onboard diagnostic display manages the aftertreatment regeneration process, and a run/idle switch reduces unnecessary engine wear during startup. The voltage selector prevents switching during operation.

Optional Tundra Package — to −40°F

The optional Tundra Package — added coolant heater, oil pan heater, battery charger, battery heater pad and heated breather hose — keeps the power flowing even in extreme cold, as low as −40°F.

Bobcat Large Generators

Compare the Large Generators

Bobcat PG125 Bobcat PG150
PG125 PG150Viewing
Prime Power Rating
Prime Power (max)125 kVA (100 kW)154 kVA (123 kW)
480 V · 3-phase · 60 Hz125 kVA / 100 kW / 151 A154 kVA / 123 kW / 186 A
240 V · 3-phase · 60 Hz125 kVA / 100 kW / 301 A154 kVA / 123 kW / 371 A
208 V · 3-phase · 60 Hz121 kVA / 97 kW / 336 A148 kVA / 118 kW / 411 A
240 V · single-phase · 60 Hz86.5 kVA / 86.5 kW / 360 A104 kVA / 104 kW / 433 A
120 V · single-phase · 60 Hz86.5 kVA / 86.5 kW / 360×2 A104 kVA / 104 kW / 433×2 A
400 V · 3-phase · 50 Hz105 kVA / 84 kW / 152 A132 kVA / 106 kW / 191 A
Voltage Configuration3-Position Switch3-Position Switch
Frequency50 / 60 Hz Switchable50 / 60 Hz Switchable
Engine
Make & ModelCummins QSB5-G11Cummins QSB5-G12
Displacement4.5 L4.5 L
Cylinders44
Power Output @ 1,800 rpm153 hp (114 kW)186 hp (139 kW)
EmissionsTier 4 FinalTier 4 Final
AftertreatmentDOC / SCRDOC / SCR
Usable Fuel Tank171.6 gal (649.6 L)171.6 gal (649.6 L)
DEF Tank24 gal (91 L)24 gal (91 L)
Runtime @ 75% Load32.4 hr26.8 hr
Dimensions & Weight (with Running Gear)
Length169.9 in169.9 in
Width71.3 in71.3 in
Height94.9 in94.9 in
Weight (Ready to Run)6,990 lbs6,990 lbs
Sound @ 23 ft, 100%68 dB69 dB

Both large generators pair a Cummins QSB5 engine (4.5 L) with an oversized Stamford alternator and ILMS load management to keep aftertreatment healthy at light loads — plus a CoolBox enclosure, integrated trailer and 110% fluid containment. These are standalone prime/standby units (no paralleling). The PG150 steps up to 154 kVA / 123 kW. Dimensions and weights are for the enclosed unit with running gear (weight is ready-to-run).

PG150

PG150 Features & Benefits

Power & Output 3
154 kVA at 69 dB(A)

One of the coolest and quietest generators on the market — at 100% load the PG150 delivers 154 kVA (123 kW) of power at a stunningly quiet 69 dB(A).

Multi-Voltage, 50 / 60 Hz Switchable

A 3-position selector covers single- and three-phase output, and a standard dual-frequency switch changes the generator from 50 Hz to 60 Hz.

Reliable in the Harshest Conditions

One of the most reliable generators available, engineered tough to withstand the harshest working conditions for a long, hardworking lifespan.

Engine & Alternator 3
Cummins QSB5-G12 — Improved Efficiency

A Cummins QSB5-G12 engine (186 hp / 139 kW, 4-cylinder, 4.5 L, Tier 4 Final) with improved fuel efficiency runs for 26.8 hours at 75% load.

Upsized Alternator with AREP

An upsized alternator with AREP protects against overload and short-circuiting, offering voltage stability and greater motor-starting capacity.

Radial Cooling Fan — An Industry First

Separate compartments for the powertrain and cooling system use radial cooling fan technology — an industry first — for one of the coolest, quietest packages on the market.

Serviceability & Controls 4
500-Hour Service Intervals

Best-in-class serviceability for maximum productivity and uptime — with 500-hour service intervals and easy serviceability whether on the jobsite or back at the shop.

Easy-Read Analog Control Panel

An analog control panel enhanced with large, brightly lit meters gives at-a-glance monitoring, and an onboard engine diagnostic display contains the controls and indicators that operate and maintain the aftertreatment regeneration process.

Run/Idle Switch + Voltage Lockout

A run/idle switch reduces unnecessary engine wear during startup, especially in extreme cold, while the voltage selector switch provides quick, easy configuration and prevents switching voltage during operation — protecting against costly downtime.

Versatile, Accessible Connections

Easily accessible connection panels add more power wiring connections, a terminal board that accepts bare wire or lugged cable, an array of twist-lock and GFCI receptacles, and an optional camlock panel.

Cold-Weather & Durability 3
Optional Tundra Package — to −40°F

The optional Tundra Package — added coolant heater, oil pan heater, battery charger, battery heater pad and heated breather hose — keeps the power flowing even in extreme cold, as low as −40°F.

User-Friendly Galvanized Steel Enclosure

A user-friendly, galvanized steel enclosure with separate powertrain and cooling compartments is engineered tough for a long, hardworking lifespan.

Easy to Tow & Maneuver

Easy to tow and maneuver around the jobsite, on purpose-built running gear with integrated 110% fluid containment.

Bobcat PG150 Portable Generator

Why Buyers Choose the PG150

154 kVA (123 kW) at a stunningly quiet 69 dB(A) — one of the coolest, quietest on the market

Reliable Cummins QSB5-G12 with improved fuel efficiency — 26.8 hours at 75% load

Upsized alternator with AREP — overload/short-circuit protection and strong motor starting

Industry-first radial cooling fan with separate powertrain & cooling compartments

Best-in-class serviceability with 500-hour service intervals

Versatile connections — terminal board, twist-lock & GFCI receptacles, optional camlock panel

Easy-read analog panel with run/idle switch and voltage-change lockout

Optional Tundra Package keeps power flowing in extreme cold — to −40°F

Customers & Applications

Who Uses the PG150 and What For

The PG150 pairs 154 kVA of clean, quiet power with industry-leading serviceability and cold-weather capability — built tough for demanding jobsites, events and standby power in any conditions.

Large Jobsites & Construction

  • High-output three-phase power
  • Strong motor starting via AREP alternator
  • 500-hour service intervals for uptime
  • Easy to tow and maneuver

Events & Entertainment

  • Stunningly quiet — 154 kVA at 69 dB(A)
  • Stable voltage for sensitive loads
  • Twist-lock, GFCI & optional camlock panel
  • Dual-frequency for varied equipment

Standby & Extreme Cold

  • Reliable backup power in harsh conditions
  • Optional Tundra Package down to −40°F
  • Run/idle switch eases cold startups
  • Remote start/stop and telematics
Bobcat PG150 Portable Generator

What Makes the PG150 Different

Prime Power
154 kVA123 kW at 69 dB(A)

One of the coolest and quietest on the market — 154 kVA (123 kW) of output at 100% load at a stunningly quiet 69 dB(A).

Engine
CumminsQSB5-G12 · 26.8 hr runtime

A Cummins QSB5-G12 with improved fuel efficiency runs for 26.8 hours at 75% load, with a standard 50/60 Hz dual-frequency switch.

Alternator
AREPUpsized Stamford

An upsized alternator with AREP protects against overload and short-circuiting, with voltage stability and greater motor-starting capacity.

Cooling
Radial FanAn industry first

Separate compartments for the powertrain and cooling system use radial cooling fan technology — an industry first — for cool, quiet running.

Serviceability
500 HoursService intervals

Best-in-class serviceability for maximum productivity and uptime — with 500-hour service intervals, on the jobsite or back at the shop.

Cold Weather (Optional)
TundraTo −40°F

The optional Tundra Package — coolant & oil-pan heaters, battery charger & heater pad and heated breather hose — keeps power flowing to −40°F.

Full Specifications

Download Spec Sheet
Power Output
Prime Power Rating154 kVA (123 kW) prime
Frequency Capability50 / 60 Hz switchable
Voltage ConfigurationMulti-voltage — 3-position switch
Runtime @ 75% Load26.8 hr @ 75% load
Sound Level69 dB(A) @ 23 ft, 100% load
480 V · 3-phase · 0.8 PF · 60 Hz154 kVA (123 kW) · 186 A
240 V · 3-phase · 0.8 PF · 60 Hz154 kVA (123 kW) · 371 A
208 V · 3-phase · 0.8 PF · 60 Hz148 kVA (118 kW) · 411 A
240 V · single-phase · 1.0 PF · 60 Hz104 kVA (104 kW) · 433 A
120 V · single-phase · 1.0 PF · 60 Hz104 kVA (104 kW) · 433 × 2 A
400 V · 3-phase · 0.8 PF · 50 Hz132 kVA (106 kW) · 191 A
Engine
Engine MakeCummins
Engine ModelQSB5-G12
Displacement4.5 L
FuelDiesel
Power Output @ 1,800 rpm186 hp (139 kW) @ 1,800 rpm
EmissionsTier 4 Final
Cylinders4
Dimensions & Capacities
Length169.9 in
Width71.3 in
Height94.9 in
Operating Weight6990 lb
Fuel Tank171.6 gal
DEF Tank24 gal (91 L)
Standard Equipment
Voltage Selection3-position voltage selector switch — quick, easy configuration; signature safety feature prevents switching during operation
Frequency50 / 60 Hz switchable (standard dual-frequency switch)
EngineCummins QSB5-G12 with ILMS (Intelligent Load Management) — improved fuel efficiency, Tier 4 Final (T4F)
AlternatorUpsized Stamford with AREP — overload & short-circuit protection, voltage stability, greater motor-starting capacity
AftertreatmentDOC / SCR + high-capacity DEF tank (no DPF); onboard engine diagnostic display manages the regeneration process
CoolingSeparate powertrain & cooling compartments with radial cooling fan technology — an industry first
EnclosureUser-friendly galvanized steel CoolBox enclosure — one of the coolest & quietest (154 kVA at 69 dB)
Connection PanelEasily accessible — terminal board accepts bare wire or lugged cable; twist-lock & GFCI receptacles; ○ optional camlock panel
Control PanelAnalog panel with large, brightly lit meters; run/idle switch reduces startup wear; remote auto start/stop + telematics
Service IntervalsBest-in-class serviceability — 500-hour service intervals
Power ModeStandalone prime or standby — paralleling not supported
Cold Weather○ Optional Tundra Package — coolant & oil-pan heaters, battery charger & heater pad, heated breather hose (to −40°F)
Fluid ContainmentIntegrated 110% fluid containment

Specifications subject to change without notice. Contact your local Carleton Equipment dealer to confirm details.

Related Products

Recently viewed

Have Questions? Fill out the form below.

Talk to a sales expert

Fill out the form and we'll connect you with the location nearest you.

First name is required.
Last name is required.
A phone number is required.
A valid email address is required.
Helps us route you to the closest location Please enter your zip code.